SolaX Power is pleased to announce the launch of the X-Hybrid Three Phase commercial battery storage inverter. The 3-Phase includes inverters ranging in size from 5 to 10kW, and with the ability to install multiple inverters in parallel, scalable battery storage for commercial applications is now a reality. The inverter is equipped with a built-in EPS (Emergency Power Supply), has multiple communication options and can be controlled remotely.
Generate solar power during the day for use in the home, when the background load is satisfied, charge your
batteries with free, clean solar energy. Discharge your stored energy during the evening when the sun has gone down, charge your batteries back
up over night on a cheaper tariff.
Our X-Hybrid Three Phase is the perfect storage solution for commercial three phase properties looking to upgrade to solar storage. The X-Hybrid Three Phase can be installed in parallel allowing for up to 100KW and over 250kWh of storage if installed with our 6.3kWh Triple Power.
With the SolaX X-Hybrid you can ensure that you never go without power, even during a power-cut. An emergency power supply or ‘EPS’ switch (only available on ‘E’ models) enables the X-Hybrid to work completely off-grid, meaning that any power you have stored on your batteries will now be used in the event of a power cut.
With the X-Hybrid you can easily set your power export limits based on local requirements. The X-Hybrid comes with built-in export control, allowing you to manage the power you generate, exactly how you want to.
X1 HYBRID 5.0T | X1 HYBRID 6.0T | X1 HYBRID 8.0T | X1 HYBRID 10.0T | |
---|---|---|---|---|
INPUT (DC) | ||||
Max. PV array Power [Wp] | A:3000/B:3000 | A:4000/B:4000 | A:6000/B:4000 | A:48000/B:5000 |
Max. DC voltage [V] | 1000 | 1000 | 1000 | 1000 |
Nominal DC operating voltage [V] | 720 | 720 | 720 | 720 |
Max. input current (input A/input B) [A] | 11/11 | 11/11 | 20/11 | 20/11 |
Max. short circuit current (input A/input B) [A] | 14/14 | 14/14 | 23/14 | 23/14 |
MPPT voltage range [V] | 125-550 | 125-550 | 125-550 | 125-550 |
Start operating voltage [V] | 180-950 | 180-950 | 180-950 | 180-950 |
No. of MPP trackers | 2 | 2 | 2 | 2 |
String per MPP tracker | A:1/B:1 | A:1/B:1 | A:2/B:1 | A:2/B:1 |
INPUT AC | ||||
Max. apparent AC power [VA] | 5000 | 6000 | 8000 | 10000 |
Max. AC current [A] | 8.0 | 9.6 | 12.8 | 16.0 |
Nominal grid voltage (AC voltage range) [V] | 400/230;380/220 | 400/230;380/220 | 400/230;380/220 | 400/230;380/220 |
Nominal grid frequency/range[Hz] | 50/60 | 50/60 | 50/60 | 50/60 |
Output AC | ||||
Nominal AC power [VA] | 5000 | 6000 | 8000 | 10000 |
Max. apparent AC power [VA] | 5000 | 6000 | 8000 | 10000 |
Nominal grid voltage (AC voltage range) [V] | 400/230;380/220 | |||
Nominal grid frequency/range [Hz] | 50/60 | |||
Nominal AC current [A] | 7.2 | 8.7 | 11.6 | 14.5 |
Max. AC current [A] | 8.0 | 9.6 | 12.8 | 16.0 |
Displacement power factor | 0.8 leading..... 0.8 lagging | |||
THDi, rated power [%] | <3 | |||
OUTPUT DC (BATTERY) | ||||
Battery voltage range [V] | 160-800 | |||
Max. continuous charge/discharge current [A] | 25 | |||
Communication interfaces | CAN/RS485 | |||
Reverse connect protection | Yes | |||
EPS OUTPUT (WITH BATTERY) | ||||
EPS MAX. continuous apparent power [VA] | 5000 | 6000 | 8000 | 10000 |
EPS rated voltage [V], Frequency [Hz} | 400/230VAC;380/220VAC; 50/60 | |||
EPS MAX. continuous current [A] | 7.2 | 8.7 | 11.6 | 14.5 |
EPS peak apparent power [VA] Duration [s] | <10000 | 60 | <12000 | 60 | <14000 | 60 | <16000 | 60 |
Changeover time [s] | <1.5 | |||
THDv, linear load | <2 | |||
EFFICIENCY | ||||
MPPT efficiency [%] | 99.9 | |||
Euro efficiency [%] | 97.0 | |||
Max efficiency [%] | 97.8 | |||
Battery charge/discharge efficiency [%] | 97.0/96.0 | 97.0/96.0 | 97.5/96.5 | 97.5/96.5 |
POWER CONSUMPTION | ||||
Power consumption (Night) [W] | 200 in standby mode, 15 in idle mode | |||
STANDARD | ||||
Safety | IEC62109-1-2 / IEC62040 | |||
EMC | EN61000-6-1/EN61000-6-2/EN1000-6-3 | |||
Certification | VDE4105 / AS4777 / EN50549 / CEI 0-21 / G98 / G99 / G100 | |||
ENVIRONMENT LIMIT | ||||
Degree of protection(according to IEC60529) | IP65 | |||
Operating temperature range [°C] | -20~+60 (derating at +45) | |||
Max operation altitude [m] | 2000 | |||
Humidity [%] | 0-100(condensing) | |||
Storage temperature [°C] | -20~+60 | |||
Typical noise emission [dB] | 40 | |||
DIMENSION & WEIGHT | ||||
Dimensions(WxHxD) [mm] | 457*654*228 | |||
Weight [kg] | 45 | |||
Cooling concept | Natural | |||
Topology | Non-isolated | |||
LCD display | Backlight 20*4 character | |||
Standard warranty [years] | 5-10 | |||