SolaX Power is delighted to announce the launch of the eagerly anticipated third generation of our market-leading solar battery storage product Hybrid inverter, which now includes a range of both single-phase and three-phase models. The X-Hybrid battery storage inverter is compatible with the leading lithium-ion battery solutions available on the market today making it the most popular energy storage solution.
Generate solar power during the day for use in the home, when the background load is satisfied, charge your
batteries with free, clean solar energy. Discharge your stored energy during the evening when the sun has gone down, charge your batteries back
up over night on a cheaper tariff.
The site of Heron Creek, Cornwall, United Kingdom. A house powered by a SolaX X-Hybrid inverter with two 6.3kWh Triple Power batteries. Since having the system installed, they are using more than half the amount of grid electricity than before.
With the SolaX X-Hybrid you can ensure that you never go without power, even during a power-cut. An emergency power supply or ‘EPS’ switch (only available on ‘E’ models) enables the X-Hybrid to work completely off-grid, meaning that any power you have stored on your batteries will now be used in the event of a power cut.
With the X-Hybrid you can easily set your power export limits based on local requirements. The X-Hybrid comes with built-in export control, allowing you to manage the power you generate, exactly how you want to.
X1 HYBRID 3.0T | X1 HYBRID 3.7T | X1 HYBRID 4.6T | X1 HYBRID 5.0T | |
---|---|---|---|---|
INPUT (DC) | ||||
Max. PV array Power [Wp] | 4000 | 5000 | 6000 | 6000 |
Max. DC voltage [V] | 600 | 600 | 600 | 600 |
Nominal DC operating voltage [V] | 360 | 360 | 360 | 360 |
Max. input current (input A/input B) [A] | 10/10 | 10/10 | 10/10 | 10/10 |
Max. short circuit current (input A/input B) [A] | 14/14 | 14/14 | 14/14 | 14/14 |
MPPT voltage range [V] | 125-550 | 125-550 | 125-550 | 125-550 |
Start operating voltage [V] | 150 | 150 | 150 | 150 |
No. of MPP trackers | 2 | 2 | 2 | 2 |
String per MPP tracker | 1 | 1 | 1 | 1 |
INPUT AC | ||||
Max. apparent AC power [VA] | 3000 | 3000 | 7000 | 3680 | 3680 | 7680 | 4600 | 4600| 9600 | 4999 | 4999 | 9999 |
Max. AC current [A] | 14.4 | 14.4 | 36.1 | 16.0 | 16.0 | 37.7 | 21.0 | 21.0 | 47 | 21.7 | 21.7 | 47.7 |
Nominal grid voltage (AC voltage range) [V] | 220/230/240(180-270) | 220/230/240(180-270) | 220/230/240(180-270) | 220/230/240(180-270) |
Nominal grid frequency/range[Hz] | 50/60 | 50/60 | 50/60 | 50/60 |
Output AC | ||||
Nominal AC power [VA] | 3000 | 3680 | 4600 | 4999 |
Max. apparent AC power [VA] | 3000 | 3680 | 4600 | 4999 |
Nominal grid voltage (AC voltage range) [V] | 220/230/240(180-270) | 220/230/240(180-270) | 220/230/240(180-270) | 220/230/240(180-270) |
Nominal grid frequency/range [Hz] | 50/60 | 50/60 | 50/60 | 50/60 |
Nominal AC current [A] | 13 | 16 | 20 | 21.7 |
Max. AC current [A] | 14.4 | 16 | 21 | 21.7 |
Displacement power factor | 0.8 leading..... 0.8 lagging | |||
THDi, rated power [%] | <2 | |||
OUTPUT DC (BATTERY) | ||||
Battery voltage range [V] | 85-400 | |||
Recommended battery voltage[V] | 300 | |||
Max. continuous charge/discharge current [A] | 20 | |||
Communication interfaces | CAN/RS485 | |||
Reverse connect protection | Yes | |||
EPS OUTPUT (WITH BATTERY) | ||||
EPS MAX. continuous apparent power [VA] | 4000 | 4000 | 5000 | 5000 |
EPS rated voltage [V], Frequency [Hz} | 230, 50/60 | 230, 50/60 | 230, 50/60 | 230, 50/60 |
EPS MAX. continuous current [A] | 21.7 | 21.7 | 26 | 26 |
EPS peak apparent power [VA] Duration [s] | 6000 | 10 | 6000 | 10 | 8000 | 10 | 8000 | 10 |
ENVIROMENTAL LIMITS | ||||
Protection class | IP65 | |||
Operating temperature range [°C] | -20~+60 (derating at +45) | |||
Max operation altitude [m] | 2000 | |||
Humidity [%] | 4~100(Condensing) | |||
Storage temperature [°C] | -20~+60 | |||
Typical noise emission [dB] | 40 | |||
DIMENSIONS & WEIGHT | ||||